Search Ctrl K
Home / Tools
THE FEUTEX TOOLKIT

Transimpedance DC Error Budget

Estimate sensor-current output and offset/bias contributions.

Electronics workspace● Runs in your browser
01 Your input
02 Your result
View or copy raw result data
FormulaVout=−I Rf; DC error≈|Ib|Rf+|Vos|
Sources and model references

Worked example

Inputs

Sensor current
1e-06 A
Feedback resistance
100000 ohm
Input bias magnitude
1e-09 A
Input offset magnitude
1e-05 V

Expected results

Signal output
-0.1 V
Worst-sign DC error
0.00011 V

Load the example in the workspace to reproduce these results. Display rounding does not change the underlying calculation.

How to use this tool

  1. Enter the labeled inputs in the indicated units.
  2. Calculate and compare every output against the stated model assumptions.

Try this example

{
  "i": 0.000001,
  "rf": 100000,
  "ib": 1e-9,
  "vos": 0.00001
}

Accuracy and scope

DC virtual-ground sensor input with unit noise gain; sensor impedance and stability excluded. Simplified analytical model; not a design recommendation or safety certification.

Is my data uploaded?

This tool runs locally in your browser. Input and output are not sent to a processing server. Copy or download your result before leaving the page.