Search Ctrl K
Home / Tools
THE FEUTEX TOOLKIT

Radiation between Large Parallel Plates

Estimate net radiative heat transfer between diffuse-gray surfaces.

Thermal workspace● Runs in your browser
01 Your input
02 Your result
View or copy raw result data
FormulaQ=σA(T₁⁴−T₂⁴)/(1/ε₁+1/ε₂−1).
Sources and model references

Worked example

Inputs

Hot absolute temperature
500 K
Cold absolute temperature
300 K
Hot emissivity
0.8
Cold emissivity
0.6
Facing area
1 m²

Expected results

Effective emissivity
0.5217391304
Net heat transfer
1609.400183 W

Load the example in the workspace to reproduce these results. Display rounding does not change the underlying calculation.

How to use this tool

  1. Enter every input in the labeled units; use measured or independently specified properties.
  2. Check the stated model assumptions before calculating.
  3. Interpret the output as a model estimate and verify it independently for the intended application.

Try this example

{
  "hot": 500,
  "cold": 300,
  "e1": 0.8,
  "e2": 0.6,
  "area": 1
}

Accuracy and scope

Very large parallel diffuse-gray plates, view factor one and nonparticipating gap. Educational engineering estimate only; not structural or safety certification, equipment selection, or operating recommendations.

Is my data uploaded?

This tool runs locally in your browser. Input and output are not sent to a processing server. Copy or download your result before leaving the page.